Skip to content

Regulation Valve

Electromotor driven valves. Your backbone for advanced fluidic systems with high precision regulation and <1s full stroke capability. Smart control unit included.

Category:

R1a

Mass ~700g
Envelope 132mm x 68mm
Envelope incl. Adapter TBD
Effective Flow Area 0-1.5mm² / KV 0.04
MEOP 130 bar
Temperature Range 150K – 300K
Media H2, O2, CH4, N2, Helium, Xenon, MMH, N2O, H2O2
Accuracy ~1% of max effective flow area
Leakrate ~1e-2 sccm/s GHe in active mode (cryo)
TRL level TRL 3 (available Q2-26)

 

R3a

Mass 800g
Adapter 238g
Envelope 132mm x 68mm
Envelope incl. Adapter 173mm  x 68mm x 124mm
Effective Flow Area 0-4.9mm² / KV 0.25
MEOP 60 bar
Temperature Range 4K – 440K
Media H2, O2, CH4, N2, Helium, Xenon, MMH, N2O, H2O2
Accuracy ~1% of max effective flow area
Leakrate ~1e-2 sccm/s GHe in active mode (cryo)
TRL level TRL 4
 

R10a

Mass 800g
Adapter 238g
Envelope 132mm x 68mm
Envelope incl. Adapter 173mm  x 68mm x 124mm
Effective Flow Area 0-42mm² / KV 2.5
MEOP 40 bar
Temperature Range 20K – 440K
Media H2, O2, CH4, N2, Helium, Xenon, MMH, N2O, H2O2
Accuracy ~1% of max effective flow area
Leakrate ~1e-2 sccm/s GHe in active mode (cryo)
TRL level TRL 3

 

R22a

Mass 800g
Adapter 238g
Envelope 132mm x 68mm
Envelope incl. Adapter 173mm  x 68mm x 124mm
Effective Flow Area 0-200mm² / KV 10
MEOP 60 bar
Temperature Range 20K – 440K
Media H2, O2, CH4, N2, Helium, Xenon, MMH, N2O, H2O2
Accuracy ~1% of max effective flow area
Leakrate ~10e-2 sccm/s GHe in active mode
TRL level TRL 6
 

R22c

Mass 800g
Adapter 238g
Envelope 132mm x 68mm
Envelope incl. Adapter 173mm  x 68mm x 124mm
Effective Flow Area 0-220mm² / KV 12
MEOP 60 bar
Temperature Range 20K – 440K
Media H2, O2, CH4, N2, Helium, Xenon, MMH, N2O, H2O2
Accuracy ~1% of max effective flow area
Leakrate ~10e-2 sccm/s GHe in active mode
TRL level TRL 4

 

R22d

Mass 800g
Adapter 238g
Envelope 132mm x 68mm
Envelope incl. Adapter 173mm  x 68mm x 124mm
Effective Flow Area 0-220mm² / KV 12
MEOP 130 bar
Temperature Range 20K – 440K
Media H2, O2, CH4, N2, Helium, Xenon, MMH, N2O, H2O2
Accuracy ~1% of max effective flow area
Leakrate ~10e-2 sccm/s GHe in active mode
TRL level TRL 3 (available Q3-26)

 

R34

Mass ~12kg
Envelope TBD
Envelope incl. Adapter TBD
Effective Flow Area 0-550mm² / KV 25
MEOP 300 bar
Temperature Range 20K – 440K
Media H2, O2, CH4, N2, Helium, Xenon, MMH, N2O, H2O2
Accuracy ~1% of max effective flow area
Leakrate ~10e-2 sccm/s
TRL level TRL 3 (available Q2-26)

 

RV100

Mass ~15kg
Envelope TBD
Envelope incl. Adapter TBD
Effective Flow Area 0-6800mm² / KV 245
MEOP 180 bar
Temperature Range 20K – 440K
Media H2, O2, CH4, N2, Helium, Xenon, MMH, N2O, H2O2
Accuracy ~1% of max effective flow area
Leakrate ~10e-2 sccm/s
TRL level TRL 3 (available Q3-26)

 

Customized

Pressure 0 – 400 bar
Temperature 4K – 450K
Flow diameter up to 100 mm
Media H2, O2, Hydrocarbons, Hydrazine & inert fluids
Lead times 14w from PO to delivery of existing designs
6-10m from PO up to delivery for scaling to new applications, faster for prototypes